Lay the backside of the hood flat on a table. Remove protective plastic film covering the upper flue and the hood. You have successfully subscribed. 8 x 3/8 screws through the lower flue side slots, Slide the upper flue upward until it is aligned with its upper flue mounting bracket. For screen reader problems with this website, please call859-342-60608 5 9 3 4 2 6 0 6 0Standard carrier rates apply to texts. endstream Make sure the outlet does not interfere with the mounting bracket fastening area, ductwork, or where the decorative flue touches the wall. ignite. This product may have sharp edges. 'XYJ4]Ljwd 5/J6gLab^Oy??vu9bHW=21y8)]uv)x&XDE$,gY;c. Do not exhaust air into spaces within. The Company reserves the right to utilize reconditioned, refurbished, repaired, or remanufactured Products or parts in the warranty repair or replacement process. Do not use to exhaust. Insert drywall anchors into the holes. /Subtype /Type1C 5. Sufficient air is needed for proper combustion and exhausting, of gases through the flue (chimney) of fuel burning equipment, to prevent backdrafting. The motor will restart when it cools down. /Rttm%fH~ }iw:w Do not exhaust air into spaces within walls or ceilings or into attics, crawl spaces, or garages. Secure the upper flue bracket to the wall using (2) no. Verify that the hood is centered and leveled. The disclaimers, exclusions, and limitations of liability under this warranty will not apply to the extent prohibited by applicable law. Always rinse well with clear water (2 or 3 times) after cleaning. IF THE FLAMES DO NOT GO OUT IMMEDIATELY. 8 x 3/8 Pan Head)7 Mounting Screws (no. If you must send the Product or part to the Company, as instructed by the Company, you must properly pack the Product or partthe Company is not responsible for damage in transit. Carefully place both flues into the recessed area of the hood top. Attach non-duct plenum with collar to upper flue using (4) no. Consequential damages include but are not limited to the cost of repairing or replacing other property which was damaged if the Product does not work properly. If the motor bearings make an excessive or unusual noise, replace the blower with the exact service blower. Thank you! /Encode [0 254] If the motor continues to shut off and restart, have the hood serviced. Slightly push aside the upper flue to avoid any damage while installing the lower flue to the hood top using (2) no. THE COMPANY SHALL NOT BE LIABLE FOR INCIDENTAL, INDIRECT, CONSEQUENTIAL, OR SPECIAL DAMAGESARISING OUT OF OR IN CONNECTION WITH THE PRODUCT, ITS USE, OR PERFORMANCE. DO NOT REMOVE the protective plastic film covering the decorative flue and the hood at this time. not by Key No. )JVG$Bm7'Vgz,[aO8%0K0cD6Q#C1L L=2mLU?E)1t}_VD80ds-+ujfDC0c=#UdI;Y1bgXe@wd#h;]o%sza4.Y$2$ajiKeUSVhxm[ >kfVr=x_wB^$5)xqOii DO NOT USE WATER, including wet dishcloths or towels . You are responsible for all costs for removal, reinstallation and shipping, insurance or other freight charges incurred in the shipment of the Product or part to the Company. 8 x 1 mounting screws through the back of the hood and into the drywall anchors. on BROAN BWP1244SS Chimney Range Hood Instructions, BROAN 353 Gable-Mount Powered Attic Ventilator Instruction Manual, BROAN BCDJ1 Undercabinet Range Hood Instruction Manual, Klarstein Athena 90 Range Hood User Manual, ancona Wall and Under Cabinet Range Hood User Manual, beyma Full Range Frequency Transducer User Manual, MONSTER MW215001 Smart Sports Watch Instruction Manual, SAINTWAY HC21SV 21.5 inch Full HD LCD POC Terminal with Bluetooth Instruction Manual, adastra MG220 Megaphone with Siren 30W User Manual, nacon PLANTRO-RIG800HS RIG 800 PRO HX Wireless Headphones User Guide, ZERFUN G8 Pro Wireless Microphone System User Manual, Airrex Infrared Heater AH-200/300/800 User Manual, 2017 Toyota Camry Hybrid LE Fuse Box Diagrams, 2017 Mitsubishi Lancer 4WD Fuse Box Diagrams, Mitsubishi Lancer Passenger and Engine Fuse Box Diagram, Mira Honesty ERD Bar Valve and Fittings User Manual, MOUNTING BRACKET LOCATION ABOVE 36 HIGH COOKTOP, Non-Duct Recirculation Filters (pair)(not shown) *, 6 Dia. The minimum hood distance above the cooktop MUST NOT BE LESS than 26.A maximum of 36 above the cooktop is highly recommended for the best capture of cooking impurities.Distances over 36 are at the installer and users discretion; providing that the ceiling height permits. INSTALL THE HOOD (Horizontally Ducted Hoods Only), INSTALL THE HOOD (Vertically Ducted Hoods Only), (Non-Ducted Hoods Only)NON-DUCT KIT MODEL ARKBWP CONTENTS. off the power unit. Be the first to learn about our special offers and sales. << Connect round metal ductwork to cap and work back towards the hood location. 8 x 1-1/2 Flat Head)7 Drywall Anchors2 Washers. We promise to keep your information private. Use a warm dishwashing detergent solution. Some jurisdictions do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. If you have questions, contact the manufacturer at the address or telephone number listed in the warranty. This warranty covers only replacement or repair of defective Products or parts thereof at the Companys main facility and does not include the cost of field service travel and living expenses. Before servicing or cleaning unit, switch power off at service, panel and lock service disconnecting means to prevent, power from being switch on accidentally. 7 $_mbynic
@
B8`p#-kWWd0[jY`w+/M*BSc9*ZAk@SzbRxJ3p/;rC$x'J]Q. 8 x 3/8 mounting screws. Before servicing or cleaning the unit, switch power off at the service panel and lock service disconnecting means to prevent power from being switched on accidentally. This discoloration is not covered by the warranty.Remove grease filters by pulling down on the metal latch tab. /Length 2205 To the extent that applicable law prohibits the exclusion of implied warranties or conditions, the duration of any applicable implied warranty or condition is limited to the period specified for the express warranty above. e6)EIgf"{lf||U7$8GzR'F5'_)F]TH_rGetd|lF hV23dp",5g;p~Y7U?K The bracket should be inside the flue. BE CAREFUL TO PREVENT. Carefully place both flues into the recessed area of the hood top. walls or ceilings or into attics, crawl spaces, or garages. Make sure that the slots of the upper flue bracket are at the bottom. Please read the specification label on the product for further information and requirements. Do not remove the protective plastic film covering the decorative flue and the hood at this time. If you cannot provide a copy of the original written limited warranty, then the terms of the Companys most current written limited warranty for your particular product will control. electrical wiring and other hidden utilities. 18 0 obj unbalanced impeller, keep drywall spray, construction dust, 4. Ad' xV (1H[Tw Make sure that the bracket is positioned inside of the lower flue flanges with the slots on top. TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR. Attach aluminum flexible duct to the damper/ductconnector with a tie wrap. For general ventilating use only.

Aluminum Duct (not shown). NOTE:On 8-ft. ceilingsHood distance above the cooktop is Minimum 26, Maximum 34 (for ducted discharge)Minimum 26, Maximum 31 (for non-ducted discharge)On 9-ft. ceilingsHood distance above the cooktop is: Minimum 32, Maximum 36 (for both ducted andnon-ducted discharge)On 10-ft. ceilingsHood distance above the cooktop is a Minimum of 32, Maximum of 36 (for both ducted and non-ducted discharge).NOTE: 10-ft. ceilings require 10-ft. Flue Extension, Model FXN58SS for ducted or non-ducted installations (purchase separately). A straight, short duct run will allow the hood to perform most efficiently. Create a signature look and focal point in any personalized kitchen with this stunning black stainless chimney hood. Boilovers cause smoking and greasy spillovers that may ignite.
INJURY TO PERSON(S) OBSERVE THE FOLLOWING: 1. HVI certified, Bright dual halogen lighting; 2-intensity settings (lamps included), Tap-touch, three-speed capacitive control features a smooth, easy-to-clean surface, Dishwasher-safe micro-mesh filters provide highly efficient grease removal. Hold hood up close to wall mounting location and plug the power cord into a wall outlet. Grease filters are dishwasher safe.Clean all-metal filters in the dishwasher using a non-phosphate detergent. To make sure there will be adequate clearance between the top of the hood and the lower flue mounting bracket for ductwork: an Elbow must be located below the lower flue mounting bracket. Unpack hood and check contents. When the service, disconnecting means cannot be locked, securely fasten a, prominent warning device, such as a tag, to the service, 3. 23 0 obj For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors. b) Always turn hood ON when cooking at high heat or when. HOMEOWNER: OPERATION AND MAINTENANCE INFORMATION ON PAGE 2. cooking flaming foods (i.e. HOMEOWNER: OPERATION AND MAINTENANCE INFORMATION ON PAGE 2. Slightly push aside the upper flue to avoid any damage while installing the lower flue to the hood top using (2) no. NOTE: non-ducted installations require a Non-Duct Kit, model ARKBWP (purchase separately). Attach (2) two non-duct recirculation filters to the sides of the blower by aligning the key lock slot and rotating until filters lock into place. /Filter /FlateDecode The bracket should be inside the flue. 8 x 3/8). 3. Be careful to avoid cuts and abrasions during installation or cleaning. * Based on "Kitchen Fire Safety Tips" published by NFPA. 8. Install wall cap or roof cap. NON-DUCTED RECIRCULATION FILTERSThe non-ducted recirculation filters should be changed every 6 months. To avoid motor bearing damage and noisy and/or. % To reduce the risk of fire and to properly exhaust air, be sure to duct air outside. Secure the upper flue to the upper flue mounting bracket using (2) no. Broan Elite EW54000 Series 36" Chimney Range Hood-Black Stainless Steel with 500 cfm and 2 halogen lighting, Broan Elite EW54000 Series 36" Chimney Range Hood-Black Stainless Steel, Proposition 65 Warning for California Residents, Powerful 500 CFM internal blower operates at 1.5 sones at normal speed. When the 5-minute delay is activated, changing the blower speed will cancel the 5-minute delay function. Use as few of them as possible. With the hood hanging in place, drill through both holes located in the inside lower back of the hood using a 5/16 drill bit. The most current limited written warranties for the Companys products can be found at www.broan.com and www.broan.ca. Secure the upper flue to the upper flue mounting bracket using (2) no.
Align the hood and center it above the hood mounting bracket.
recirculating range stainless steel broan ducted non kit hood zoom range inch hood hoods haier convertible Be carefule to avoid. 2. Any products containing: chloride, fluoride, iodide, bromide will deteriorate surfaces rapidly. Tilt the filter downward and remove it. automatically shut off the motor if it becomes overheated. 6. You know you have a Class ABC extinguisher and you, B. The hood is operated using the push buttons on the front panel. /Range [0 1 0 1 0 1 0 1] Make sure that the bracket is tight against the wall. Pull down the metal latch tab, push the filter into position, and release. Carefully place both flues into the recessed area of the hood top. 8 x 3/8 mounting screws. 7. REPLACEMENT PARTS AND REPAIRSIn order to ensure your unit remains in good working condition, you must use Broan-NuTone LLC or Venmar Ventilation ULC genuine replacement parts only. Remove the upper flue from inside the lower flue. The bottom of the hood MUST NOT BE LESS than 26 and at a maximum of 36 above the cooktop for best capture of cookingimpurities. Use duct tape to make all joints secure and air-tight. Always use cookware appropriate for the size of the surface element. Always use cookware appropriate for. Warranty Period and Exclusions: Broan-NuTone LLC and Venmar Ventilation ULC (either being the Company) warrants to the original consumer purchaser of its product (you) that the product (the Product) will be free from material defects in the Product or its workmanship for a period of one (1) year from the date of original purchase (or such longer period as may be required by applicable law). Gently lower the hood until it securely engages the bracket. The fire is small and contained in the area where it. /Length 396 Tighten the screws completely. Use duct tape to seal the joints between ductwork sections. This warranty covers only Products sold to original consumers in the United States and Canada by the Company or its U.S. and Canadian distributors authorized by the Company. Your hood motor has a thermal overload which will automatically shut off the motor if it becomes overheated. If the motor. Replacement parts can be ordered on our website: www.broan.comfor US customers only. SMOTHER FLAMES with a close-fitting lid, cookie sheet, or, metal tray, then turn off the burner. Crpes Suzette, Cherries Jubilee, c) Clean ventilating fans frequently. TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSON(S) OBSERVE THE FOLLOWING: TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:a) Never leave surface units unattended at high settings. Home Broan BROAN BWP1244SS Chimney Range Hood Instructions, To register this product visit:www.broan-nutone.com orwww.broan.ca. Use duct tape to make all joints secure and air-tight. Ducted fans must always be vented to the outdoors. 9. Your email address will not be published. THE COMPANY DISCLAIMS AND EXCLUDES ALL OTHER EXPRESS WARRANTIES AND CONDITIONS, AND DISCLAIMS AND EXCLUDES ALL WARRANTIES AND CONDITIONS IMPLIED BY LAW, INCLUDING WITHOUT LIMITATION THOSE OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. If a framing member is not present, drill two 5/16 diameter holes where shown. When cutting or drilling into a wall or ceiling, do not damage electrical wiring and other hidden utilities. This could cause a violent steam explosion. The grease filters should be cleaned frequently. When cutting or drilling into wall or ceiling, do not damage. This warranty gives you specific legal rights, and you may also have other rights, which vary from jurisdiction to jurisdiction. Installation work and electrical wiring must be done by, qualified personnel in accordance with all applicable codes, and standards, including fire-rated construction codes and, 4. 8 x 3/8 screws through the lower flue side slots. Long duct runs, elbows, and transitions will reduce the performance of the hood. The limited warranty period for any replacement parts provided by the Company and for any roducts repaired or replaced under this limited warranty shall be the remainder of the original warranty period (or such longer period as may be required by applicable law). 6. Tighten the screws completely. A sleek, low-profile design enhanced by a dazzling finish. 8 x 1 mounting screws. Be careful when installing the decorative flue and hood, 10. Install (2) washers and (2) no. Grease should not be allowed to accumulate on fans or filters.d) Use proper pan size. Please read specification label on product for further, Manual will be automatically added to "My Manuals", Ventilation Hood Broan BW50 SERIES Instructions Manual, Ventilation Hood Broan BW5330SS Installation Use And Care Manual, Ventilation Hood Broan BWP1244SS Instructions Manual, Ventilation Hood Broan BW5830SS Installation Use And Care Manual, Ventilation Hood Broan BEST BER02IS Manual, Ventilation Hood Broan B3030SS Instructions Manual, Ventilation Hood Broan BC2130SS Installation Instructions Manual, Ventilation Hood Broan B5630SS Instruction Manual, Ventilation Hood Broan B5630SS Instructions Manual, Ventilation Hood Broan B5630SS Quick Start Manual, Ventilation Hood Broan B5330SS Installation Instructions Manual, Ventilation Hood Broan BDF SERIES Installation Manual, Ventilation Hood Broan BDF Series Installation Instructions Manual, Page 6: Install Upper Flue Mounting Bracket. 8 x 3/8 pan head screws. Slide up the upper flue upward until it is aligned with its upper flue mounting bracket. See illustration below. Installation work and electrical wiring must be done by qualified personnel in accordance with all applicable codes and standards, including fire-rated construction codes and standards. Follow the heating equipment, manufacturer's guidelines and safety standards such as, those published by the National Fire Protection Association, (NFPA), the American Society for Heating, Refrigeration, and Air Conditioning Engineers (ASHRAE) and the local, 5. Two installers are recommended because of the size of, 8. Position the electrical outlet within the space covered by the decorative flue and where it will not interfere with the round duct. Use this unit only in the manner intended by the manufacturer. DO NOT REMOVE the protective plastic film covering the decorative flue and the hood at this time. If you have questions, contact the manufacturer at the.
broan nutone chimney pyramidal The electronic filter clean reminder ensures they will always maintain peak efficiency, Install hood so that the bottom of the unit is 24" to 30" above the cooking surface. Do not use over cooking equipment greater than 60,000. During construction/renovation, cover the range hood to make sure no dust sticks to the stainless steel surface. To cancel the delay-off function before the end of the 5-minute cycle, press again on the delay-off push button or select another blower speed. Remove protective plastic film covering the flue and the hood. hazardous or explosive materials and vapors. Your hood motor has a thermal overload which will. Follow the heating equipment manufacturers guidelines and safety standards such as those published by the National Fire Protection Association (NFPA), the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities. 8 x 1 mounting screws through the hood back and into the drywall anchors. BTU/hr. 2. The foregoing warranties are exclusive and in lieu of any other warranties and conditions, express or implied.

This product may have sharp edges. Boilovers cause smoking and greasy spillovers that may. To avoid motor bearing damage and noisy and/or unbalanced impeller, keep drywall spray, construction dust, etc. Mounting height may be affected by ceiling height, Ducted telescopic flue accommodates ceiling heights from 8' to 9'. endobj >>

Heat oils slowly on low or medium settings.b) Always turn the hood ON when cooking at high heat or when cooking flaming foods (i.e. NEVER PICK UP A FLAMING PAN You may be burned. 8 x 1 mounting screws. To reduce risk of fire and to properly exhaust air, be sure, to duct air outside. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel-burning equipment to prevent back-drafting. For ducted installation only:Install both damper flaps inside the blower exhaust opening, ensuring the pins are top-oriented. 8 x 3/8 screws through the lower flue side slots. Flue extension for higher ceilings is also available (sold separately), This hood can be installed non-ducted with the use of the accessory Non-Duct Kit (model number HRKMBLS sold separately). tj@E /Size [255] Heat oils slowly on low or medium settings.
broan zephyr anzio Proper maintenance of the Range Hood will assure the proper performance of the unit. NOTE:Minimum hood distance above cooktop must not be less than 26.Distances over 36 above the cooktop are at the installers and users discretion providing that ceiling height and flue length permit. /Domain [0 1] << This warranty also does not cover (a) normal maintenance and service, (b) normal wear and tear, (c) any Products or parts which have been subject to misuse, abuse, abnormal usage, negligence, accident, improper or insufficient maintenance, storage or repair (other than repair by the Company), (d) damage caused by faulty installation, or installation or use contrary to recommendations or instructions, (e) any Product that has been moved from its original point of installation, (f) damage caused by environmental or natural elements, (g) damage in transit, (h) natural wear of finish, (i) Products in commercial or nonresidential use, or (j) damage caused by fire, flood or other act of God or (k) Products with altered, defaced or removed serial numbers.