Manual activation of the valve, in case of malfunction, is enabled through the LCU DLS device and / or the main valve control circuit. We use cookies to improve your website experience. Contact themnow and find your Solutions! The valve controls by the versatile DOROT ConDor controller that enables all control functions, or combination of functions, at extreme accuracy. Cla-Val Altitude Control Valves regulates the high water level in reservoirs without the need for floats or other devices. The valve maintains the maximum level continuously. The LCU DLS is an electric device which enables activation of hydraulic valves, by means of a latching (pulse) solenoid, using standard 9V batteries. FLDI2, equipped with float pilot model 70-610, enabling level differentials of 5-40cm (2-16). Altitude & Level Control Valves, Cla-Val Company Global Headquarters and Factory1701 Placentia AvenueCosta Mesa, CA USA 92627 (949-722-4800). The differential between the maximum and the minimum levels is adjustable. The standard valve closes when the water rises to the requested maximum level and opens when the water level drops to the preset minimum point. The valve is controlled by a PLC controller that enables local or remote control of various functions such as, time related operation, the batching of liquid, and conditional (automatically modified) control parameters, in various applications. It closes when the water rise to the requested maximal level, and opens fully when the water level drops to the preset minimal point. The main valve is controlled by a highly sensitive pilot, located outside the tank. Accurate and repeatable differential level control, Easy access - no float is located in the tank/reservoir. Share your thoughts with other customers. 0009092maximum water level. The float pilot can either be assembled on the main valve (for above-level installation), or can be connected to the main valve by command tubes. Pre-shaped reinforced diaphragm for easier assembly and improved longevity. Non-modulating float valves open fully when the liquid level in a tank reaches a pre-set low point. Mey-Yavne- How to provide water to an entire city and remain in control? Dorot Series 300 Electronic Control Valve (30-EC) is an automatic, solenoid control valve, activated by the pressure of the pipeline. FL- Modulating Water-Level Control valve - Series 300, FL - Modulating Float Controlled Valve - Series 100, FL - Modulating Float Controlled Valve - Series 500, FLDI1/FLDI2 - Differential Water-Level control valve - Series 300, FLDI - Differential Float Controlled Valve - Series 100, FLDI - Differential Float Controlled Valve - Series 500, AL - HYDROSTATIC-ALTITUDE CONTROL VALVE - Series 300, AL - Altitude Pilot Controlled Valve - Series 100, FLEL - Electrically-activated level control valve - Series 300, FLEL - Electric Float Controlled Valve - Series 100, FLEL - Electric Float-Controlled Valve - Series 500, EC - Electronically - controlled valve (ConDor) - Series 300, Surge preventing - stepped closure addition, Open Field - sprinklers & drip irrigation, 80 Series -Turf Irrigation 80-1, 3/4, DAV P KA (Combination Air Valve: Kinetic-Automatic), DAV-P-SA Surge arresting device for DAV valves, DAV LP K (kinetic Low Pressure Air Valve), GAER - Flanged-Butterfly Valve - Series 13, GAER - Flanged-Butterfly Valve - Series 20, GAER - AWWA-C515 Resilient Seated Gate Valve, GAER - Resilient Seated Gate Valve - PN 10-16, GAER - Resilient Seated Gate Valve - PN25 F5, Tirat Zvi Case Study - Smart Water ConDor Installation, Use of Dorot model 30-4-PRM(Pu) - Givat Yoav Resort Power Supply, High-expansion foam plant UNI EN 13565 - Case Study by FSE PROGETTI, 30 6'' PR HyMod Water Distribution London, 30 8'' PR HyMod Water Distribution Belfast, 30 12'' PRM HyMode Agua y Dranaje Monterrey Mexico, Pressure Management Troms, Norway Use of DOROT model 30-PR, SOUTHERN AQUADUCT CITY OF SALTA ARGENTINA, PR-EL-100S-8"-Pump-Control Irrigation Argentina, 300S-Pressure regulation and stabilized storage tank, Use of Dorot Altitude Controlled Pilot - PS - Pilot Valve - Costa Rica, Granadilla Water Tank, Dorot delivers Non Revenue Water ("NRW") Solutions in Bogota, Colombia, Dorot Delivers Complete Pressure Reducing Stations in Argentina. Modulating float valves maintain a constant liquid level in a storage tank by compensating for variations in supply or demand and are used to control the flow into or out of a tank by either opening or closing on a rising level. Can be controlled by any pulse- activating controller. Envinfra Solutions Pvt. The two standard 9V batteries provide, approximately, one year of operation, assuming the system is activated twice an hour. Optional Addition: Stepped Surge-Preventing Closure. It closes when the water rise to the requested maximal level, and opens fully when the water level drops to the preset minimal point. High level opening/low level closing valves are supplied on request. The opening operation allows for the tank to be refilled to a pre-set high point, at which time the valve closes drip-tight. In need for further information? The pilot allows for differential adjustments between the maximum and minimum level. Regulates at a stable mode, regardless of valve-size, down to near-zero ow. In case you have a question about the products, get in touch with our team to know more and clarify your doubts right away. Altitude & Level Control Valves, Electronic A float valve controls the main valve, closing it when the water reaches maximum level, and opening it when the water drops to its preset minimum level. Thus, eliminating the need for a special low ow plug-design (such as V-port) or a bypass valve. Mounted on the inlet of the tank / reservoir, below the water level . A standard and simple single-chamber valve design, provides smooth operation. Model 31, 31A for high pressure (up to 25 bar / 350 psi). Ltd. Privacy Policy | Terms & Conditions | Copyright Policy. The valve is activated by the hydrostatic pressure of the water level. FLDI1, equipped with float pilot model 70-550, enabling level differentials of 5-160cm (2- 63). Optional Addition: Surge-Preventing Closure (SA). Mounted on the tank / reservoir inlet, below or above the water level. The main valve is controlled by a float valve, located in the tank or reservoir and set at the required. Since 1946! Optional Addition: Surge-Preventing Closure (SP). Conversion to a double chamber is a patented option. Hydraulic Toll Free Number 1800-120-8002 | Telephone Number +91-124-4235-627. The pilot opens or closes the valve in response to the static pressure of the water. A recommended option is using the Dorot ConDor controller that enables the selection from a vast range of pre-programmed control functions and their combinations. The main valve is controlled by a highly sensitive pilot, located outside the tank. Cla-Val manufactures several different types of level control valves. Altitude valves can be configured for one-way or two-way flow depending on system requirements and can be furnished with auxiliary controls for multiple functions such as pressure sustaining, pressure reduction, rate-of-flow control, solenoid override or other parameters as needed. Reduced periodic inspection\maintenance labor: Highly accurate and reliable electronic control Low power actuation, Controlled by Dorot ConDor valve controller or by a third party controller. All control ports are fitted with SST sleeves for preventing corrosion-blockage. Optional Addition: Stepped Surge-Preventing Closure. The Differential Float Valves are available in two versions: The main valve is supplied in two models: Mounted on the tank / reservoir inlet, below or above the requested water level. The control-trim is fitted with a self-flushing, inline control-filter. An electric sensor float, located in the tank/reservoir, sends a command to a solenoid controlled valve. Shipping charge applicable as per serviceability, This valve is the substitute of the traditional float ballcock, which can be applied to various systems of high water tanks, pools, water towers of the industry and civil construction, etcAutomatic control, low self-complementary water, water full automatic stopFour intakes, large flow of waterBeautiful appearance, small size, practical, simple installationWithout electricity, easy to use, long life, low failure rate, saving water resource, MSR TOP VALL 32mm 1'' Tankbuddy Valve Float Valve for Big Water Tank, MSR 1/2 Inch Automatic Water Level Control Valve - Pack of 2 Pcs, 1 Inch Automatic Water Level Control Valve, MSR - 1/2 INCH OUTSIDE VALVE Automatic Water Level Control Valve( PACK OF 2 ), Automatic Water Level Control Valve Inside, 1 Inch Automatic Water Level Control Valve Inside Type, CAST IRON BALL VALVE SCREW END BSP-F CAST IRON 15 MM, CAST IRON BALL VALVE SCREW END BSP-F 20 MM, AMTECH CAST IRON BALL VALVE SCREW END BSP-F 25 MM, AMTECH CAST IRON BALL VALVE SCREW END BSP-F 32 MM, AMTECH CAST IRON BALL VALVE SCREW END BSP-F 40 MM, CAST IRON BALL VALVE SCREW END BSP-F 50 MM, CAST IRON BALL VALVE SCREW END BSP-F 65 MM, CAST IRON BALL VALVE SCREW END BSP-F 80 MM, AMTECH CAST IRON BALL VALVE SCREW END BSP-F 100 MM. Closes when the water level rises to the float location, preventing overflow, and opens when the water level drops. Activated by An Electric Float pilot located in the tank / reservoir. The LCU DLS valve is controlled at the ground level - so, unlike hydraulic float pilot located on the top level of the tank- it is not affected by the static pressure of the water level. A Float valve (model 70-550) controls the main valve, closing it when the water reaches maximum level, and opening it when the water drops to its preset minimum level. Floating, low-friction internal-trim design, guided by unique LPT device. Dorot model FLDI1/FLDI2 is an automatic, pilot controlled, level control valve, activated by the pressure of the pipeline. Enabling adjustable differential of the max / min levels. The main purpose of the LCU DLS is to control the maximal and minimal water levels in tanks and reservoirs, using a very sensitive Pressure switch. The differential between the water levels is adjustable. FLEL - Electric Float-Controlled Valve An automatic, level control valve, activated by an electric float that operates the main valve by a solenoid. All right reserved. The differential between the water levels is adjustable. The pilot allows for differential adjustments between the maximum and minimum level. These non-throttling valves remain fully open until the pre-set shut-off point is reached. The valve maintains the maximum level continuously. The differential between the maximum and the minimum levels is adjustable, at a wide range. The valve is mounted on the tank or reservoir inlet, below or above the requested water level . The main valve will fully open when the solenoid activated and will close drip tight when the solenoid de-energized, thus enabling accurate and reliable differential level control. Our experts in Hydraulic Engineering & Water Control Systems are at your service! Dorot Saves Water to Aguas de Valencia - Spain, Aguas de Sevilla Utilizes Dorot Control Valves, City of Limassol, Cyprus, recognizes Dorot's Pressure Management Solutions as Effective and Profitable, Dorot Control Valves contributes to Water Savings, Big Project Requires Great Valves - MONTEREY, Maintaining quality crops in the desert 'Dorot' supporting you all the way, Dorot Control Valves Solutions make Puerto Vallarta an -even more- appealing touristic destination, Dorot Italy Delivers Impressive Project for Water Optimization Use in Sicily, Top UK Water Utility Demonstrates Dorot 24" S-300 Pressure Regulation Valves Fulfils Their Needs, Adjusts the inlet flow to the reservoirs outlet flow. Optional Addition: Stepped Surge-Preventing Closure. By navigating our site, you agree to allow us to use cookies, in accordance with our Cookies Policies, Water Level Control Valve Inside Type, side Inner Water Automatic Float Valve Water Level Control Valve Used for Water Tank. WRAS Approval no. The pilot opens or closes the valve in response to the static pressure of the water. Optional addition: surge-preventing closure (SP). Innovating Water Control-Solutions. Model 30, 30A for medium pressure (up to 16 bar / 230 psi). Optional Addition: Surge-Preventing Closure (SP). The main valve is controlled by a float valve, located in the tank or reservoir and set at the required maximum water level. How Dorot saves the Chinese 1 million USD per day?